Service
Principal business areas in the field of service maintenance
Supply of spare parts and materials for PJSC "KTW" steam turbines:- Rotors with capped and integral disks;
 - Impeller wheels;
 - Diaphragms;
 - Blades;
 - Sealing rings;
 - Front and rear rotor bearings.
 
- Providing recommendations on terms of maintenance, scope of work and recommended list of spare parts, taking into account the manufacturer's experience;
 - High-quality diagnostics and qualified repair of steam turbine equipment of our own manufacture in the following areas: Complete service maintenance, rotors repair, auxiliary equipment repair;
 - Inspection, diagnostics, analysis of operation and assessment of the technical condition of the customer's equipment, on-site specialists visit with recommendations on the scope of required work, development of technical solutions for repair and maintenance;
 - Repair, modernization, and reconstruction works supervision.
 
Reducing gears manufactured and repaired by PJSC "KTW"
| Type of reducing gear | Power | Gear ratio | Weight (tons) | Input Frequency | |
Single-stage  | 
					With horizontal and vertical alignment of gear axes  | 
					up to 10 MW  | 
					up to 5  | 
					up to 10  | 
					on customer's request  | 
				
Double-stage  | 
					up to 15 MW  | 
					up to 9  | 
					up to 60  | 
				||
Planetary  | 
					up to 30 MW  | 
					up to 17  | 
					|||
Multipliers  | 
					
						 up to 10 MW  | 
					
						 up to 5  | 
					
						 up to 10  | 
				||
| 
						 Worm-type reducing gears  | 
					
						 
  | 
					
						 up to 11 KW  | 
					
						 up to 32  | 
					
						 up to 1  | 
				
Manufactured and repaired pumps
| 
						 Pump Type  | 
					
						 Flow m3/h  | 
					
						 Pressure head m  | 
					
						 Speed  | 
					
						 Positive suction head, m  | 
					
						 Fluid temperature, °С  | 
					
						 Efficiency, %  | 
					
						 
						 Type of electric engine  | 
				
| 
						 ЭКН  | 
					
						 6-300  | 
					
						 25-300  | 
					
						 1500-3000  | 
					
						 0,8-1,8  | 
					
						 125  | 
					
						 up to 67  | 
					
						 АИР,РА 
  | 
				
| 
						 ПН 150-50  | 
					
						 150  | 
					
						 500 - 560  | 
					
						 2380 - 3200  | 
					
						 9,5  | 
					
						 105  | 
					
						 65  | 
				|
| 
						 ПН 1500-350  | 
					
						 1500  | 
					
						 3600  | 
					
						 4500  | 
					
						 100  | 
					
						 160  | 
					
						 83  | 
					
						 drive turbine  | 
				
| 
						 ПЭ 160-140  | 
					
						 160  | 
					
						 1480  | 
					
						 3000  | 
					
						 8  | 
					
						 160  | 
					
						 65  | 
					
						 4АЗМ-1000/ 6000, 6000V, 50Hz, 1000kW  | 
				
| 
						 ПНХ 100-60  | 
					
						 100  | 
					
						 600  | 
					
						 3000  | 
					
						 10  | 
					
						 40  | 
					
						 65  | 
					
						 5АН355В2У3, 400kW  | 
				
| 
						 ЦНС 150-50  | 
					
						 150  | 
					
						 50  | 
					
						 3000  | 
					
						 6,5  | 
					
						 80  | 
					
						 65  | 
					
						 ВА200L2 380V, 50Hz, 45kW  | 
				
| 
						 ПТА 50-50  | 
					
						 50  | 
					
						 525  | 
					
						 6000  | 
					
						 8  | 
					
						 105  | 
					
						 0,4  | 
					
						 turbine drive  | 
				
| 
						 Д 10000-210  | 
					
						 10000  | 
					
						 210  | 
					
						 3000  | 
					
						 65  | 
					
						 up to 80  | 
					
						 83  | 
					
						 8MW  | 
				
Before being shipped to the customer pumps are tested at the specialized stands
Condensers manufactured and repaired by PJSC "KTW"
Heat exchanger surface area  | 
					from 40 m2 to 4000 m2  | 
				
Number of water passes  | 
					single pass, two pass, four pass  | 
				
Structural design  | 
					welded, assembled  | 
				
| 
						 By connection to the turbine  | 
					
						 basement, axial, suspended  | 
				
| 
						 By type of tubes mounting  | 
					
						 roll forging, roll forging + seal welding  | 
				
| 
						 Tube Material  | 
					
						 LO (tin brass), MNZh (copper-nickel alloy), stainless steel, titanium  | 
				
- Condensers are equipped with all necessary safety, control and measurement systems;
 - Water chambers are adapted for the possible connection to the ball cleaning system;
 - It is possible to equip the condensate collector with a dissolved oxygen removal system;
 - Individual design on order is possible.